29 Typical
Charpy V-Notch Impact Properties As
Welded CO2
Testing Temp. ft.-lbs.
(J) 72°F
(22°C) 43
(58) 0°F
(-18°C) 20
(27) Typical
Undiluted Weld Metal Analysis (%) Gas
C Mn
Si P
S Mo
CO2
0.061 0.69
0.41 0.011
0.019 0.48
Standard Diameters
.045" (1.2 mm), .052" (1.4 mm), 1/16"
(1.6 mm) Recommended
Welding Parameters pages 74 & 75 Additional
Low Alloy Wires listed on page 73