16
Important
Info
Cast Iron
Alloys
Tool Steel
Electrodes
Nickel
Alloys
Nickel
Silver
Alloys
Copper
Alloys
Aluminum
Alloys
Silver
Alloys
Steel
Alloys
Metal
Removal
Electrodes
Hardfacing
Alloys
Misc.
Alloys
Packaged
Products
All-State
Fluxes
Safety
Appendices
Procedures When welding high carbon steel, preheat to 300°-400°F (149°-204°C), do not preheat manganese steel. Hold the electrode at an angle of 15° in the direction of travel with as short an arc as possible without allowing the coating to touch the weld pool. Stringer beads are preferable. Weaving should be limited to 2 1/2 times electrode diameter. Clean slag thoroughly between passes. For vertical welding, the electrode should be held perpendicular to the work piece using a very slight oscillation from side to side on the root bead. When welding overhead, hold a short arc with no oscillation of the electrode. Diameters and Recommended Amperages 1/8" (3.2mm)—110-150 5/32" (4.0mm)—140-190 3/16" (4.8mm)—180-240 Identification WH stamped on electrode coating. Packaging All sizes in 8-lb. (3.63 kg) containers.